DOME CAMERATK-C215VP4U/ETK-C215VP12U/EINSTRUCTIONSFor Customer Use:Enter below the Serial No. which is located on the body. Retain this information fo
10IntroductionCamera (continued)GBaseMount the base to the ceiling, wall or electrical box before mounting the camera.(A Pg. 21)(A Pg. 31)H Fastening
11Camera (Interior)M Rotation Knob ( TK-C215VP4U/E only)Rotate the lens unit to adjust the inclination of the image. (A Pg. 25)NRotation Center Mark (
12IntroductionSet the video setting switches on the camera unit before mounting it.To set the switches, use a fine-tipped screwdriver.A [RESET/SPOT] R
133.[SYNC] Synchronization system selection switch.This switch sets the synchronizing system for the camera.INT:This is set for internal synchronizati
14IntroductionSet the video setting switches on the camera unit before mounting it.To set the switches, use a fine-tipped screwdriver. A [IRIS LEVEL]
15G Function selection switches1. [AGC] Auto-gain control switch.Setting this switch to AONB automatically increases the sensitivity even when the bri
16Installation and Connection● Turn off the power of devices to be used before connecting the cables.● Read through the “Instruction Manual” of the de
17The maximum connection distance varies with the type of cable used. Please refer carefully to the table for each cable during connection.* Be sure t
18Installation and ConnectionElectrical Specifications of Alarm Input Terminals(TK-C215VP12U/E only)● To prevent penetration of noise in the internal
19Follow the procedures below to connect/set this unit.Turn off the power of devices to be used before connecting the cables.KKKKKKThe right sequence
2IntroductionThese are general IMPORTANT SAFEGUARDS and certain items may not apply to all appliances.1. Read all of these instructions.2. Save these
20Installation and ConnectionRemove the dome cover, followed by setting the video image switches.1.Removing the dome coverRemove the dome cover by unf
21Remove the camera unit from the base and mount the base to the ceiling or wall.When mounting to a wall, follow the procedures by replacing areas ind
22Installation and Connection1.Connecting the coaxial cable (A Pg. 17)Lower the protection cover and connect the connectors. Upon connecting, cover th
23Fill the piping hole and mounting hole with a sealing material, mount the camera unit to the base, and insert the silica gel.1.Fill the hole with se
24Installation and Connection4.Inserting the silica gel suppliedTake out the silica gel from the aluminum package, insert it into the silica gel inser
25Upon mounting the camera, adjust the images while checking the actual image.Mounting the test monitorConnect the [MONITOR] terminal of this unit to
26Installation and ConnectionAdjusting the angle of view, focus and brightnessUpon determining the imaging direction, adjust the angle of view, focus
27Adjusting the brightnessUsually, adjustment of the brightness is not required. When this is necessary, adjust the iris level accordingly.To darken :
28Installation and Connection䡵 TK-C215VP12U/E● 2 types of angle of view may be selected for TK-C215VP12U/E. In general, set in a way such that the hom
29䢇 Registering alarm positionFor registering the angle of view during monitoring when there is an alarm input.1.Check that the [ALARM POSITION] indic
3Safety PrecautionsThis Class B digital apparatus complies withCanadian ICES-003.Due to design modifications, data given in thisinstruction book are s
30Installation and ConnectionAfter setting is complete, mount the inner dome to the camera.1.Mounting the inner domeMount the inner dome to the 3 clip
31Note: ● Make sure that the dome cover is firmly fastened.Otherwise, the humidity level may rise
32Installation and ConnectionUse the piping hole to mount the camera.Mounting the camera using the piping hole at the bottom surface of the base1.Sett
33Mounting the camera using the piping hole at the side surface of the baseIf the camera cannot be mounted directly to the ceiling, mount it to the pi
34Installation and ConnectionAs a general characteristic unique to CCDs, white-spots may appear on the screen with age.In order to reduce this phenome
35TK-C215VP4_JP.book Page 35 Thursday, November 2, 2006 10:51 AM
36Others䡵 CameraSignal system:U type : Based on NTSC standardE type : Based on PAL standardScanning frequenciesU type : 15.734 kHz (Horizontal), 59.94
37䡵 LensFocal lengthTK-C215VP4U/E : 2.8 mm to 10 mm (variable)TK-C215VP12U/E : 3.8 mm to 45.6 mm (variable)Zoom ratioTK-C215VP4U/E : Approx. 3.6TK-C21
38Others䡵 Dimensional Outline Drawing[Unit: mm (inch)]* Specifications and appearance of this unit and related products are subject to change for prod
39Focus chartTK-C215VP4_JP.book Page 39 Thursday, November 2, 2006 10:51 AM
4Introduction䢇 The unit is to be powered by a DC 12 V or an AC 24 V power supply.䢇 The unit is to be powered by a UL Listed DC 12 V or an AC 24 V powe
© 2006 Victor Company of Japan, Limited LST0519-001ATK-C215VP4U/E TK-C215VP12U/EDOME CAMERATK-C215VP4_JP.book Page 40 Thursday, November 2, 2006 10
5Thank you for purchasing this product.(These instructions are for: TK-C215VP4U/TK-C215VP4E/TK-C215VP12U/TK-C215VP12E.)Before beginning to operate thi
6IntroductionIntroductionSafety Precautions ... 3Characteristics ... 5Table of
7Storage and Location of Use䢇 Do not install this unit at the following locations.● Places that are exposed to vapor or oil, such as kitchens.● Places
8IntroductionMaintenance䢇 Turn off the power before performing maintenance.䢇 Clean the dome cover using a lens cleaning cloth (or soft cloth). Wiping
9CameraAMounting hole ⳯ 2Use these when mounting the camera to the ceiling, wall or electrical box.(A Pg. 21)(A Pg. 31)Note: